All products – for tunnels and metro
Products Designed Specifically for Tunnels, Metro and Underground
The primary goal of tunnel ventilation is to maintain safe and healthy air quality for occupants. In the event of a fire or other emergency, proper ventilation can help manage smoke levels and provide a safe exit route for occupants. Tunnel ventilation systems can consume significant amounts of energy, so it’s important to consider energy efficiency in system design and operation.
CFD-02TM – High temperature tunnel damper
Flamgard type CFD-02T High Temperature Tunnel Damper has been designed for bolting directly onto walls and floors or bolting or welding to steel support frames. The damper has been successfully tested and operated up to 400ºC for 2 hours. To ease installation these dampers can be supplied with pre-drilled flanges and mounting frames.
CFD-01 Fire Damper – A0 (A60), H0(H120) or E120S and BS476 Fire Classifications
Flamgard CFD-01 Fire damper. EN 1366-2 tested for categories ‘E’ Integrity ‘S’ Smoke . Maximum single module size 3100×3100 mm (DNV-GL), 2050×2050 mm (ABS) for A class applications. H class applications are also accommodated at various sizes.
- Low leakage in accordance with EN 1751 Class 3 and Class C
- ATEX rated
- SIL 2 rated to IEC 62508-2:2010
- NORSOK complaint
CCD-01 – Heavy Duty Control Damper
Flamgard type CCD-01 Heavy Duty Shut-Off and Control Damper has been specifically designed to meet the rigorous duty required in a hazardous environment where robust construction and dependable operation are of prime importance.
- Can also be utilized as an High Integrity Isolation damper and/or Volume control damper
- SIL 2 rated to IEC 62508-2:2010
- ATEX rated
CCD-02 – Medium Duty Control Damper
Flamgard CCD-02 Medium Duty Control Damper has been specifically designed for the industrial market where medium weight, construction and dependable operation are of prime importance. These versatile dampers are suitable for automatic and manual operation and may be used for: system balancing, pressure control, fresh air re circulation and many more functions.
- Can also be utilized as an High Integrity Isolation damper and/or Volume control damper
- SIL 2 rated to IEC 62508-2:2010
- ATEX rated
CCD-C1 – Circular Control Damper
Flamgard type CCD-C1 Circular Control Damper has been designed to fit into circular ductwork systems where space is restricted. These versatile dampers are suitable for automatic and manual control and may be used for fan shut-off, fresh air re circulation and many more functions.
- SIL 2 rated to IEC 62508-2:2010
- ATEX rated
UTA – Gastight shut-off damper
Halton UTA dampers are used to shut-off and balance airflow rates in high pressure ductworks. Dampers meet international standards for rectangular and round ducts. In the open position, the blades face the direction of flow and do not cause a significant pressure loss. The UTA is used as a shut-off, gas and balancing damper in applications where tightness and reliability are important.
- A closed damper fulfils the requirement of leakage class 3 (EN1751:2014) for size ≥ 300×300 mm (stainless steel seals) and for size ≥ 150×150 mm (silicon seals)
- Classification of casing leakage (EN1751:2014) class C
UTP – Balancing damper
Halton UTP dampers are used to balance airflow rates in high pressure ductwork. Dampers meet international standards for rectangular and round ducts. In the open position, the blades face the direction of flow and do not cause a significant pressure loss.
- Leakage class of a closed damper according to EN 1751:2014 class 1. Tested size 1000×1000 mm
- Classification of casing leakage (EN 1751:2014) class B
CBD-01 – Heavy Duty Backdraught Damper
Flamgard type CBD-01 Backdraught Damper has been designed to give maximum efficiency under arduous conditions and is suitable for fitting with the air flow in one direction only.
- SIL 2 rated to IEC 62508-2:2010
CBD-02 – Medium Duty to Low Leakage Backdraught/Non Return Damper
Flamgard type CBD-02 Damper has been designed to give maximum shut-off under back-flow conditions and is suitable for fitting with the air flow in one direction only.
- SIL 2 rated to IEC 62508-2:2010
CPR01 – Pressure Relief Damper
Flamgard type CPR-01 Pressure Relief Damper has been designed to give maximum efficiency under arduous conditions and is suitable for the air outlets of electrical equipment rooms, control rooms and living quarters. These areas are maintained at a higher pressure than surrounding areas to prevent the ingress of hazardous gases. The differential pressure is usually 63 N/m² although this may be increased to provide a greater safety margin.
BLD – Non-Return Damper
Halton BLD non-return dampers are used in offshore and marine applications to prevent backflow through ventilation ductwork.
BRD – Pressure-Relief Damper
Halton BRD pressure-relief dampers are used in offshore, marine and industrial applications to regulate the pressure in the ductwork system.
BLD-01 – High-Pressure Blast Damper
Flamgard type BLD-01 High Pressure Blast Damper is of a high performance design suitable for the arduous conditions encountered in offshore/onshore oil and gas, marine, nuclear, tunnel and industrial environments. The Blast Damper has been independently blast performance tested and is certified by SIRA to 04ATEX9322 for ATEX Group II Category 2 G/D use by SIRA.
BLD-02 – Medium-Pressure Blast Damper
Flamgard type BLD-02 Medium Pressure Blast Damper is of a high performance design suitable for the arduous conditions encountered in offshore/onshore oil and gas, marine, nuclear, tunnel and industrial environments. The Blast Damper has been independently blast performance tested and is certified bvy SIRA to 04ATEX9322 for ATEX Group II Category 2 G/D use by SIRA.
BDH – Blast protection damper
Halton BDH blast dampers protect against overpressure in offshore, onshore and heavy industry ventilation systems. The BDH blast damper can be installed in rectangular ducts or wall openings. When the blades are in the open position, the device does not cause significant pressure loss, noise or flow disturbance.
CWL-01 – Fixed Blade Weather Louvre
Flamgard CWL-01 Fixed Blade Weather Louvre has been designed specifically to meet the arduous conditions encountered offshore and is suitable for fitting to duct inlets or exhausts.
HL – Triple Deflection Eliminator
Flamgard type HL high efficiency triple deflection moisture eliminator has been designed specifically to meet the arduous conditions encountered in offshore and marine environments and is suitable for fitting to duct inlets or exhausts where higher water removal rates can be achieved, than with conventional louvres.
SL – Double Deflection Eliminator
Flamgard type SL high efficiency double deflection moisture eliminator has been designed specifically to meet the arduous conditions encountered in offshore and marine environments and is suitable for fitting to duct inlets or exhausts.